This article walks through installing your Vue, from preparing your panel to wiring the harness, and answers common questions that come up along the way. Before you begin, download the official Emporia Vue 3 Home Energy Monitor Installation Guide. All guides are on the Product Documentation page.
Safety: Working inside an electrical panel can cause serious injury or death. Turning off the main breaker does not de-energize the service mains. If you are not comfortable working inside an electrical panel, installation should be performed by a skilled person such as a licensed electrician or other qualified professional, following the Vue Installation Guide and your local electrical code.
Have a Vue 2? This article works for both models, since CT placement and wire harness wiring are the same. The differences are in the gateway itself. For step-by-step connections, use the Vue 2 Installation Guide.
Not sure whether to do this yourself? See Does Installing a Vue Require an Electrician?
Before You Start
Locate your service disconnect. It may be outside the panel you’re working in.
Check your Wi-Fi signal next to the panel. The Vue works on 2.4 GHz Wi-Fi only, not 5 GHz. Use your phone at the panel to check the 2.4 GHz signal. If it’s weak or missing, plan on a 2.4 GHz Wi-Fi extender or, on the Vue 3, an ethernet connection.
Plan where the Vue will mount. Inside the panel is recommended, at least 2 in from live parts. If there isn’t room, the Vue can mount outside the panel as long as it stays dry. If you’re not sure there’s room, have an enclosure on hand before you start, and confirm the spot once the cover is off.
Outdoor panels need a weatherproof enclosure with knockouts for the harness, CT leads, and antenna.
Check that you have the breakers you need. The Vue needs one breaker for each phase wire: 1 for single-phase, 2 for split-phase, 3 for 3-phase. An empty breaker is simplest. If none are free, you can splice onto an in-use breaker (covered in the Connect the Wire Harness section).
Gather your tools. Insulated gloves, protective eyewear, Phillips and flathead screwdrivers, a flashlight or work light, and a multimeter or voltage tester (recommended).
Not sure a Vue fits your home? See Will a Vue Work for My Home?
When You’re Ready
Make sure the work area is clean and well lit. Set up a work light if needed, since the home’s lights will be off when power is cut.
Cut power from the electrical panel. Turn off the branch circuit breakers, then the main breaker and/or service disconnect. Danger: The service mains stay energized even with the main breaker off.
Remove the panel cover. Remove the screws and the cover.
Use your multimeter or voltage tester to confirm the breakers you’ll be working on are de-energized.
Find a place for the monitor. Choose a spot at least 2 in from any live parts, excluding insulated cables. The Vue shouldn’t touch the panel’s interior insulation or be attached to any energized part. If there isn’t room, see Plan where the Vue will mount above.
Prepare Your Internet Connection
The Vue connects over 2.4 GHz Wi-Fi, wired ethernet (Vue 3), or both. It doesn’t support 5 GHz Wi-Fi.
Wi-Fi: Remove a knockout from the panel and feed the antenna cable through it. Screw the cable into the coaxial connector on the Vue, then plug the knockout hole. The antenna must sit outside the metal panel enclosure. It’s fine to place it inside a wall.
Ethernet (Vue 3): Run a Cat5e or better cable from your router, switch, or modem to the panel. Remove a knockout, feed the cable through, and plug it into the LAN port on the Vue.
No knockout available? The Vue and antenna can stay entirely inside the panel, but the metal enclosure may weaken the Wi-Fi signal. If you have connection problems, try a 2.4 GHz Wi-Fi extender placed close to the panel.
Having trouble connecting? If the app can’t find your Vue during setup, or it goes offline later, see Vue Not Connecting: Bluetooth and Wi-Fi Troubleshooting.
Install the Main CT Sensors
The main CTs are designed to measure your whole-home usage. Most US homes (split-phase) use 2. See Your System Type and How Many CTs You Need if you’re not sure.
If you have solar, where the CTs go depends on how it’s connected. See Monitoring Solar with Your Vue before you place them.
Danger: The service mains are energized.
Open the clasp on each CT and clamp it around one of the main service cables, on live (hot) conductors only, never neutral. Clamp onto insulated conductors only. The “Breaker” label (K→L on the Vue 2) points toward the breakers, away from the utility meter.
Plug each CT into the A, B, or C port on the right side of the Vue (top of the Vue 2). Any order works, and the Vue detects the voltage phase automatically.
Optional: to reduce clutter, you can shorten the CT wires. See Adjusting CT Wire Length first, since the black and white wires must match the labels on the Vue.
Installing flexible sensors? They install differently from standard CTs, including which way they face, and need their own power supply. Follow the Emporia Vue 3 Flexible Current Sensors Installation Guide, and see Flexible Sensor Installation for a step-by-step overview and video walkthrough.
Connect the Wire Harness
The wire harness has four wires: black, red, blue, and white. It powers the Vue and lets it measure voltage on each phase. The black, red, and blue wires connect to breakers, one per phase in your system, and the black wire also powers the Vue. White connects to the neutral bus bar, as well as any unused red or blue wire. For more on what each wire does, see How the Wire Harness Works.
Plug the harness into the Vue. Insert the plug into the port on the left side of the Vue 3 (bottom on the Vue 2) until it clicks. The wires can be shortened to reduce clutter.
Connect the white and neutral wires for your system type:
Split-phase (most US homes, 120/240V): White and Blue to the neutral bus bar.
Single-phase (1 live main): White, Red, and Blue to the neutral bus bar.
Three-phase (Wye only; 3 live mains): White to the neutral bus bar.
Connect the phase wires to breakers.
Wire to an empty breaker or an in-use breaker.
Empty breaker: Wire the harness lead directly to the breaker. Any breaker size works, the Vue uses very little power.
No empty breaker: Use the splicing wires and wire nuts included with the Vue, so only one conductor lands on the breaker terminal. Turn the breaker off, disconnect its wire, join that wire, the harness lead, and a splicing wire with a wire nut, then connect the splicing wire to the breaker. The included splicing wires are 14 AWG. If the breaker’s existing wire is thicker than 14 AWG, use a splicing wire that matches its gauge and meets your local electrical code.
AFCI, RCD, or GFCI Breaker
Connect the white wire to that breaker’s neutral terminal alongside the black wire, not to the neutral bus bar. The black wire powers the Vue, so its current has to return through the same breaker. Without this change, the breaker will trip after the Vue is installed. Red and blue wires don’t need this, since they don't use any power. Leaving the white wire on the bus bar is the most common cause of breaker trips. See Wire Harness Installation Issues: Breaker Trips After Install for the full troubleshooting steps.
Install the Branch CT Sensors (Optional)
If your Vue came with 50A CTs, you can monitor individual circuits. You can also purchase additional CT sensors through our Emporia Energy Website. Each Vue device has up to 16 connections for 50A branch CT sensors.
Open the clasp on a CT and clamp it around the hot wire of the breaker you want to monitor, with the CT’s “Breaker” label facing the breaker. A backwards CT shows incorrect or negative readings. (Vue 2: the K→L imprint points away from the breaker.)
Plug the CT into a numbered port (1–16) on the Vue. Note the port number so you can name the circuit in the app.
After you set up your account in the Emporia Energy App and onboard your device, you will want to customize the settings for your Branch CT sensors. Go to the Menu, Manage Devices, select your Vue monitor, and tap Circuits. Select the connected circuits according to their port number, then give each one a name and circuit type.
Monitoring a multi-pole breaker? See Multi-Pole and 240V Circuits.
Have solar? Set the circuit type to Solar/Generation and turn on Bidirectional. See Monitoring Solar with Your Vue.
Additional information regarding CT Sensors installation found in CT Sensor Installation.
Close Up the Panel and Finish Setup
Check and photograph. Make sure the CT plugs and wire harness are secure, since the ports can’t be reached once the cover is on. Take photos of your installation in case you need to contact support.
Restore power. Replace the panel cover and screws. Turn on the main breaker or service disconnect, then any branch breakers you turned off.
Finish setup in the app. Open the Emporia app (download links below), create an account if you don’t have one, and follow the prompts to add your Vue. Have your Wi-Fi name and password ready. You'll want to be near the device during onboarding, and allow Bluetooth and location when prompted.
Download the Emporia Energy App
Download the app before attempting to connect the Vue. Onboarding devices must be done on a smartphone or tablet. You are not able to connect a device through a laptop or desktop.
Voltage error during setup? During setup the app checks the voltages the Vue detects against the number of main CTs you installed. If they don’t match, see Wire Harness Installation Issues: Voltage Detection Error During Setup.
Frequently Asked Questions
What if there isn't enough room in my panel for the Vue?
What if there isn't enough room in my panel for the Vue?
The Vue can mount outside the panel as long as it stays dry. The harness wires and CT leads will need to enter the panel through a knockout or opening.
Can I install a Vue on an outdoor panel?
Can I install a Vue on an outdoor panel?
The Vue isn’t weatherproof. Mount it inside the panel enclosure if there’s room. If not, use a separate weatherproof enclosure next to the panel, with knockouts or conduit for the harness, CT leads, and antenna.
Can I power the Vue from an outlet instead of the wire harness?
Can I power the Vue from an outlet instead of the wire harness?
No. The harness powers the Vue and gives it the voltage reference it needs to calculate watts. Without it, readings will be inaccurate.
The standard CT sensor won’t fit. What are my options?
The standard CT sensor won’t fit. What are my options?
For main conductors, try the spring clamp (larger 24 mm window, no tools) or flexible sensors for tight spaces and bus bars. For branch circuits, the large-diameter 50A CT fits wires the standard 50A clamp won’t. See How CT Sensors Work for sizes and options.
Do I need a dedicated circuit for the wire harness?
Do I need a dedicated circuit for the wire harness?
No. The harness can connect to any available circuit breaker, as long as each phase wire lands on a different phase and is properly pigtailed to breakers already in use.
What if I have a Delta 3-phase system?
What if I have a Delta 3-phase system?
The Vue is designed for Wye systems, where each phase has a neutral and a similar voltage. The Vue measures each phase against the neutral, so Delta systems aren’t supported. This includes “high leg” setups, where one phase is noticeably higher in voltage than the others, which would produce inaccurate readings. Not sure what you have? See Will a Vue Work for My Home? or send a photo of your panel to our Customer Support team.
What do the lights on my Vue mean?
What do the lights on my Vue mean?
Any lit LED indicates that the Vue has power. Green means connected over Wi-Fi and blue means connected over ethernet. Solid means connected to the internet, and blinking means it's attempting to connect to the internet via your router. See Vue LED Behavior (Gen 3) or Gen 2.
Don't see your question? Contact our Customer Support team.
Feedback and Suggestions
This knowledge base is continuously updated to provide the most helpful guidance for Emporia customers. If you found this article unclear or have suggestions for improvement, please contact our Customer Support team.